MIL-DTL-83413/8D
TABLE IV. Available lug sizes.
B & H type jumper assembly. 1/ 2/ 3/ 4/ 8/
Copper terminals
Code letter lug size
For stud
(All types except type C)
designation
size
SAE-AS25036
SAE-AS20659
Insulated
Uninsulated
T
.250
-116
...
(6.35)
U
.250
...
-141
(6.35)
K 6/
.312
-117 5/
...
(7.94)
L 6/
.312
...
-108 5/
(7.94)
M 7/
.375
-118
...
(9.53)
N 7/
.375
...
-129 5/
(9.53)
1/ Dimensions are in inches. Metric equivalents are given for information only.
2/ Unless otherwise specified, tolerance is + .005.
3/ Resistance readings to be taken at the junction of terminal barrels and
tongues.
4/ Lightning current tests applicable to type G and H assemblies only.
5/ Size #8 AWG wire only.
6/ Lug size designators K, & L, correspond to lug size D in Rev B, but were
broken out separately for clarification.
7/ Lug size designators M, & N, correspond to lug size E in Rev B, but were
broken out separately for clarification.
8/ For supersession information see table VII.